28.385913
77.263282
As per Map site address /Designated, demarcation of plot, we will done situation at Nasar Pur Disst. Ghaziabad.
230 MM thick and 2.1 meter boundary wall of RCC/ BRICK filled boundary wall at site will be made of Fly Ash/Clay brick with coulumn beam structure. The heights of boundary wall will be 6FT plaster will be done on both side.
Concrete / Apex road will be made at the site. Internal road size will be as per layout plan, and it will be RCC Trimix Road.
Yes, Footpath will be made by Cement concrete stone and Grass Pavers.
All the drinking water supply to be through terrace tank of required capicity . Municipal water supply will used for drinking water and also collected in under ground water reservoris and Pumped to terrace Tanks.
A well laid sewer system connected to external sever system is proposed, will be constructed at site, all water drain will come connect in the Sewerage system and used with STP. its size will be as per the design calculation.
Drain having minimum width of 150 mm will be provide for collection. Separate drainage line is used as per the design requirement.
Landscape area is provided as per local Building Bye Laws. Along with this ,we will also do gardening and plants.
The tree will be planted at all suitable located of the project and will provided as per the approved layout Plan and as per Local Building Bye Law.
Electric supply provided through individually transformer and DG set. All electric supply and Street light is provided as per the layout plan and Local Authority Norms.
N/A
Disposal system of sewage and sullage water is being used through STP which is used for landscape and flushing purpose.
All the solid waste manage as per the biodegradable waste converted in to compost and non biodegradable delivered to registered agencies.
Rain water harvesting pits shall be provided for ground water recharging and over flow to be discharged the munilcipal drain. Low flow water fixture being used for water conservation and STP water is used for landscape and flushing purpose.
Specific U- value glass is used for energy management and used soler energy lights in common area.
Fire safety system and fire protection system is installed in the building as per the NBC norms.
Proper water supply and sanitary facilities every floor , including public health service provided as per local building bye law.
As per the environment management plan and disaster management plan , all provision are made including assemble points.
NA
Showing 1 blocks with 51 units
Total Area
6112.44 m²
65793.69 ft²
Total Units
63
1 different types
Blocks & Floors
1
5 floors across all blocks
Parking
0
0 garages, 0 open
Total Area
3236.54 m²
34837.79 ft²