28.950294
77.686874
DEMARCATION OF PROJECT HAS BEEN COMPLETED BY BOUNDRYWALL OF 1.2 METER HEIGHT. Providing 1.2 meter height fencing with angle iron post 50--50-6 mm at 3m c/c with 0.4 embeeded in ground in cc 1-5-10 stone agg, 40 mm nominal size and every 10 th post situated provided with welded steel wire and fixed to iron post .
A 1.2 METER HEIGHT BOUNDRYWALL CONSTRUCTED AND COMPLETED ON ENTIRE PROJECT AREA.
REQUIRED THICKNESS OF B.C. WITH SEALCOAT OR INTERMEDIATE BASE OVER SUB-BASE WILL BE DONE IN THE WIDTH .
AN M-15 GRADE OF PAVERBLOCK INTERLOCKING TILES WILL BE LAID IN THE PROJECT FOR THE WALKING AREAS. TILE WILL BE 3 TO 4 INCH THICK AND THE COLOUR PATTERNS WILL BE LASTING AND VISIBLE ALL HOURS.
OVERHEAD WATER TANK OF 150000 LITRE TO BE PROVIDED. Providing and fixing of 140mm dia PVC pipe pve speical such as bends. tee and other materials. Boring of tubewell and installation of pump of 5 HP.
A SEVERAGE WILL BE COLLECTED THROUGH RCC HUME PIPES ARRANGEMENT AND INSPECTION CHAMBERS LEADING TO THE STP TANK OF THE PROJECT, FROM WHERE THE SEVERAGE WILL BE DISPOSED OFF. Providing and laying class NP2 prssure pipes with collar tested to 40sm head, joined 450 meters. Construction of brick massonry mainhole class designation with cement mortar in 1-5 ratio of 38 numbers.
SURFACE DRAIN WILL BE LAID ON LEAN CONCRETE BAD EARTH ON COMPACTED EARTH IN REQUIRED SIZE WITH BREAK WORK 1X4 PLASTER OVER IT. Drains in cementmortar 1 to 6 ratio including earth excavation and disposal after refilling of excavated earth 7.5 cm. Thick bed concrete 1-5-10-25cm thick CC 1-2-4 ratio for filling hunches including 12 mm plaster.
NOT APPLICABLE
NOT APPLICABLE
ELECTRIC LAYOUT AND CAPACITY WILL BE INSTALLED TO SUFFICE THE DOMESTIC USE OF THE PROJECT. THE LOAD SANCTION WILL BE TAKEN FROM ELECTRIC DEPARTMENT. 24 poles to be installed .
NOT APPLICABLE
STP BASED ON BLANKET REACTOR SYSTEM WITH AIRPUMPS FOR AERATION SYSTEM AND HYPO CLORIDE SOLUTION WITH CHEMICAL CATALYST SYSTEM AND AFTER MAKING SLUDGE CLEAN IT WILL BE PUMP TO THE FILTER AND THEN WILL BE DISPOSED.
AREA FOR SOLID WATER SHALL BE PROVIDED AS PER MDA APPROVED DRAWING AND SHOWED IN DEVELOPMENT PLAN.
RAIN WATER HARVESTING SYSTEM -2 wells to be installed.
NOT APPLICABLE
FIRE PROTECTION AND FIRE SAFETY SYSTEM WILL BE INSTALLED AT ALL THE CROSSING OF THE COLONY. 4 fire extnguishers to be installed.
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
No: LEGAL REPORT OF SALE DEED NO 8557 TO PROVE OWNERSHIP OF SARASWATI BUILDCON | Date: 20-07-2024
Showing 1 blocks with 4 units
Total Area
0.00 m²
0.00 ft²
Total Units
0
1 different types
Blocks & Floors
1
1 floors across all blocks
Parking
0
0 garages, 0 open
Total Area
2999.00 m²
32280.94 ft²