As per sanction plan this is Irregular shaped plot. Having total 1 no. of entry gate and exit gate, from the 12m wide road, Site is surrounded by other plots on one side and another side proposed 60 mtr wide master plan road (master plan 2031)
1.8 - 2.1m high and 200 mm thick brick work and rcc work in column and beam. MS Board enterance and exit gates are developed with boundary.
Trimix / asphalt/interlocking Brick/RCC road will be used as per design suggested by the Architect for internal road.
We would not provide any footpath
All apartments shall be provided with potable water for household activities and STP treated water for flushing. Clear water may also be used, and user can have their individual RO system as per their requirements.
The sewerage network shall comprise Double Wall Corrugated (DWC) drain pipes designed for sewer applications. For diameters of 250 mm and above, Reinforced Cement Concrete (RCC) pipes of Class NP2, conforming to IS: 458, shall be used under normal slopes and site conditions. Manholes shall be constructed in brick masonry as per the National Building Code (NBC) with sizes as follows: 1. 900×800 mm (up to 900 mm depth) 2. 910 mm dia (900–1670 mm depth) 3. 1220 mm dia (1670–2290 mm depth) 4. 1520 mm dia (2290–4180 mm depth) Steel Fiber Reinforced Concrete (SFRC) or Fiber Reinforced Plastic (FRP) manhole covers conforming to IS: 12592 shall be provided as per site requirements.
The storm water drainage shall be designed to effectively collect and discharge surface runoff. RCC NP2 pipes conforming to IS: 458 shall be used for main drains, while DWC pipes may be used in non-traffic or landscaped areas. Brick masonry manholes shall be provided at junctions and changes in direction or gradient, with SFRC or FRP covers as per load requirements.
We will provide green area with the different activities, and the green area will have gaming facilities for kids.
We will provide many types of trees all along the boundary wall & green area
We will design & implement the system as per local electricity Board and will consider centralized Transformer, HT panel, LT Panel, Feeder Pillar and DG back for common service like External lighting, Fountain, STP, Pump room etc.
Not Applicable
Modular Sewerage system shall be Provided. All Sewerage water shall be going to the STP and overflow from the STP shall be connect with the Municipal sewerage system., when come into force.
There are a proper garbage collection area provided for the solid waste management.
We will suggest to individual to use low flow fixtures as well dual flush cistern and raw water harvesting system to reduce the water consumption and improve the ground water level.
We will use LED lights fitting in external area as well as solar lights. In Pump room also all the equipment shall have energy efficient motor. And we will suggest to individual also to use.
We will provide Fire Fighting facility in common areas while Individual owner can install their own system as per their and local authoritys requirement.
Not Applicable
We will have staircases which will be provided with emergency exit doors and emergency exit gates
Not Applicable